TRANSIT Ultimate Quick Install Guide

Power Supply

Linear 24vdc 2-3 AMP

Cabling

Shielded twisted 6 (18-22 Gauge) for communication wiring.
A separate twisted pair (14-18 Gauge) for the power supply.

Tools

  • 1 Phillips screwdriver to open and access the reader
  • 1 small flathead screwdriver for landing the wiring
  • Wire Strippers

Wiring

mceclip0.png mceclip1.png mceclip3

Grounding

mceclip4.png

Continuity is created by landing a jumper between the 12v ground powering the access control panel to the 24v ground powering the reader.

Plug and Play

Out of box the reader is set to output W26 with a FC of 10 with Dipswitches 2,6, & 7 “OFF”. Can be changed at the reader level.

Orientation

mceclip5.png mceclip6.png
When mounted Horizontally (normal application) the reader emits an 80- degree wide by 40-degree high oval beam. When mounted Vertically the reader emits a 40- degree wide by 80-degree high beam. This is recommended for multi-lane applications to
prevent cross talk

Tag Enrollment

mceclip7.png

Out of box the reader is set to output W26 with the FC of 10

The orange circle is the 6-digit W35 or higher ID #
The blue circle is the 5-digit W26 ID#
(do not include the – or # after the dash.)

 

Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request