Power Supply
Linear 24vdc 2-3 AMP
Cabling
Shielded twisted 6 (18-22 Gauge) for communication wiring.
A separate twisted pair (14-18 Gauge) for the power supply.
Tools
- 1 Phillips screwdriver to open and access the reader
- 1 small flathead screwdriver for landing the wiring
- Wire Strippers
Wiring
Grounding
Continuity is created by landing a jumper between the 12v ground powering the access control panel to the 24v ground powering the reader.
Plug and Play
Out of box the reader is set to output W26 with a FC of 10 with Dipswitches 2,6, & 7 “OFF”. Can be changed at the reader level.
Orientation
| When mounted Horizontally (normal application) the reader emits an 80- degree wide by 40-degree high oval beam. | When mounted Vertically the reader emits a 40- degree wide by 80-degree high beam. This is recommended for multi-lane applications to prevent cross talk |
Tag Enrollment
|
Out of box the reader is set to output W26 with the FC of 10 The orange circle is the 6-digit W35 or higher ID # |