uPASS Target and OSDP

The Process of switching from Standard to OSDP Communication is done with a USB type A connection and the UHFTool.

mceclip1.png

The firmware of the uPASS Reach (UHF processor) can be updated using UHFTOOL.

The latest version can be downloaded here: 

An additional driver may need to be downloaded at the location below. http://www.ftdichip.com/Drivers/CDM/CDM21224_Setup.zip

The 1st connection you will need to connect with Baud rate 115200. Once connected to the UHFTOOL, select Update Firmware option 1 or 2  to update firmware to OSDP. You will then connect with Baud rate 9600 and protocol as OSDP and click “OK”.

mceclip2

Wiring

mceclip3

Point-to-point communication

For point to point communication it is recommended to install a termination resistor.

Please use the RS485 set (art.no. 8500681) for convenient installation.

mceclip4.png

Multi-drop communication

Multi-drop communication requires an addressable communication protocol, such as OSDP. For multi-drop communication install the termination resistor only on the last reader. Please use the RS485 set (art.no. 8500681) for convenient installation.

mceclip5.png

UHF Tags OSDP Output

The Serial output is different in that Wiegand is reliant on Parity Bits and the Serial output is not. The Hex String is sent in a “96 bit Packet” in Serial Protocol and this includes the configured leading and trailing parity bits. Below is the example of how the information is sent through.

mceclip4

When you update to the OSDP firmware you can connect and view what the reader is seeing and sending. Above highlighted is the tag in the UHFTool and below is the raw hex format in the OSDPTool.

mceclip5

If the packet of information is sent “as is” in raw hex string, it will not output the UID printed on the tag. There is an additional bit at the end of the hex string. This is the bit for parity in Wiegand. You will need to set up your panel with an offset of 1 bit. You will need to set up the panel to know where to look for the ID printed on the UHF Tag (FC 72-79 and TID located in bit 80-95).

Sample read in Raw hex format and Card ID information location.

 0010000101010110001001001101  HEX String sent to the OSDP panel: 215624D 

       000010101011000100100110    FC: 10   ID#:45350 

 

Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request